PS3 |
Total |
|
|
|
|
|
|
|
Total |
120.0 |
85.0 |
20.0 |
|
15.0 |
|
|
|
Average |
103.4 |
84.7 |
11.0 |
-4.2 |
12.0 |
|
1.0 |
|
Codename |
|
Features (17% per feature - 5 features) |
Extra Credit |
Accuracy of modeliing (Closeness of snap fit, boss- 2% per feature) |
Iproperties |
Late Time |
Late penalty factor (1.0 / 0.7 / 0.4 / 0) |
Comments |
Milwaukee , Wisconsin |
120 |
85 |
20 |
|
15 |
|
1 |
Nice job! |
St. Paul , Minnesota |
119 |
85 |
20 |
|
14 |
|
1 |
Rib sketch not fully constrained |
Baltimore , Maryland |
119 |
85 |
20 |
|
14 |
|
1 |
1.Should turn off visibility of workplane 2.File submitted before
due time, made some minor changes(feature rename, visibility) after
that |
Tucson , Arizona |
119 |
85 |
20 |
0 |
14 |
|
1 |
Name your features accordingly, well done |
Denver , Colorado |
118 |
85 |
20 |
-2 |
15 |
|
1 |
Feature requirement 4 does not fit in side wire closely |
Phoenix , Arizona |
118 |
85 |
20 |
-2 |
15 |
|
1 |
1.Feature requirement 4 is not fitting closely with side wire |
Lincoln , Nebraska |
118 |
85 |
20 |
|
13 |
|
1 |
iproperty not fully populated(designer/author) |
Jersey , New Jersey |
118 |
85 |
20 |
-2 |
15 |
|
1 |
feature 4 is not totally right at shape, good job! |
San Francisco , California |
116 |
85 |
20 |
-4 |
15 |
|
1 |
1. Rib sketch not fully constrained 2. No draft angle on ribs |
Jacksonville , Florida |
116 |
85 |
20 |
-4 |
15 |
|
1 |
1. Requirement 4 is not fit well with side wire 2.No fillets on the
backside base of rest |
Seattle , Washington |
116 |
85 |
20 |
-2 |
13 |
|
1 |
Rest fillets not completed, name features in the model, full
constrain your sketches |
Austin , Texas |
116 |
85 |
20 |
-4 |
15 |
|
1 |
Swtich mounting features are not completed ( lack of several ribs),
snap fit type is wrong |
Tampa , Florida |
115 |
85 |
20 |
-4 |
14 |
|
1 |
1. Snapfit platform ribs is not inclined. 2.Feature requirement 4 is
created by linear pattern, goes through side plastic cover 3.Rename
your features in the browser |
Honolulu CDP, Hawaii |
115 |
85 |
20 |
-4 |
14 |
|
1 |
snap fit closeness, feature 4 is wrong at shape, name your features
modeled |
Kansas , Missouri |
114 |
85 |
20 |
-6 |
15 |
|
1 |
1. Turn off visibility of your added workplane and axis 2.Snapfit
platform is not correct 3.Switch control moungting base lack
ribs |
Anchorage , Alaska |
114 |
85 |
20 |
-4 |
13 |
|
1 |
1.iProperty not fully populated(author) 2.Feature requirement 4 is
not correct. Try extrude from the side rather than bottom 3. Snapfit
platform base is not correct |
Anaheim , California |
112 |
85 |
20 |
-2 |
9 |
|
1 |
rest need to be filletted at the back, iproperty info is missing,
name your features |
Fresno , California |
112 |
85 |
20 |
0 |
7 |
|
1 |
iproperty is missing, sketches not fully constrained, name your
features, too many fillet operations separately |
Portland , Oregon |
111 |
85 |
20 |
-4 |
10 |
|
1 |
1. iproperty not fully populated(designer/author) 2. Turn off
visibility of the workplane 3.ribs number is not 10. 4.Requirement
4 dimension is not correct. 5.ribs sketch not fully constrained |
Louisville , Kentucky |
111 |
85 |
20 |
-4 |
10 |
|
1 |
Rest fillets not completed, snap fit closeness, iproperty missing |
Hialeah , Florida |
111 |
85 |
20 |
-4 |
10 |
|
1 |
rest need to be filletted at the back, feature 4 is wrong at shape,
iproperty info is missing |
St. Petersburg , Florida |
110 |
85 |
20 |
-2 |
7 |
|
1 |
snap fit closeness, iproperty information missing, fully constrain
your sketch, close work planes after modeling, used fillets too many
times |
Cleveland , Ohio |
109 |
85 |
20 |
-10 |
14 |
|
1 |
1.Snapfit not fit closely 2.Feature 4 is not fit with side wire
properly 3.Switch pad base lacks ribs and is far from required shape
4. Snapfit base is solid 5. rib sketch not fully constrained |
San Antonio , Texas |
109 |
85 |
20 |
-4 |
8 |
|
1 |
# of ribs is wrong, snap fit closeness, iproperty is missing
information needed, name your file properly |
Minneapolis , Minnesota |
108 |
85 |
20 |
-4 |
7 |
|
1 |
feature 6 penetrates through the cover, feature 4 is wrong with no
round cut through at the end, name your features, fully constrain
your sketches, turn off the visibility of the work plane,iproperty
missing |
Fremont , California |
107 |
85 |
20 |
-6 |
8 |
|
1 |
Snap fit closeness, press mount features for green part are wrong,
draft base of snap instead of adding ribs, iproperty missing, fully
constrain your sketch, name your features |
New Orleans , Louisiana |
106 |
85 |
10 |
-4 |
15 |
|
1 |
Snap fit facing direction and closeness |
Wichita , Kansas |
106 |
85 |
10 |
-4 |
15 |
|
1 |
Number of ribs are wrong, snap fit direction is wrong. |
Cincinnati , Ohio |
105 |
85 |
10 |
-4 |
14 |
|
1 |
1. Rib number is not correct, rib height is too low 2.Rib & Pin
hole sketch not fully constrained 3.No fillets on backside of rest |
Arlington , Texas |
105 |
85 |
10 |
-4 |
14 |
|
1 |
1. No draft angle on ribs, not fit for molding 2.Ribs sketch not
fully constrained 3.Snapfit platform is not correct |
Fort Wayne , Indiana |
104 |
85 |
10 |
-6 |
15 |
|
1 |
1. Feature requirement 4 is not correct 2.Snapfit is too small and
weak 3.No fillets on backside of rest base |
Stockton , California |
104 |
85 |
10 |
-4 |
13 |
|
1 |
Sketches are not fully constrained, snap fit closeness, press mount
closeness |
Dallas , Texas |
104 |
85 |
10 |
-4 |
13 |
|
1 |
rest features need to be fillet at the back, snap fit closeness,name
your file properly |
Norfolk , Virginia |
102 |
85 |
10 |
-2 |
9 |
|
1 |
no draft angle for ribs, iproperty info is missing, sketch not fully
constrained |
Sacramento , California |
101 |
85 |
20 |
-12 |
8 |
|
1 |
No draft angle of ribs, fillets of the rest are too small, wrong
shape of bases for snap fit, too thick of bases for snap fit, snap
fit closeness, switch mounting feature is not completed, iproperty
incomplete, name your features and fully constrain your sketches |
Tacoma , Washington |
101 |
85 |
10 |
-2 |
8 |
|
1 |
shape of feature 4 is wrong with no round cut at the end, iproperty
is missing, turn off visibility of work planes and reference line,
name your features, |
Pittsburgh , Pennsylvania |
99 |
85 |
10 |
-6 |
10 |
|
1 |
1.iproperty not populated(Author/Designer) 2.Ribs height is too
low, can not support side cover properly 3.No fillets on the
backside of rest 4.Snapfit not fit in with orange side part
5.Snapfit platform goes through side cover 6. Ribs sketch not fully
constrained 7. file name is not following the remane rule(lack of
your id) |
Atlanta , Georgia |
99 |
85 |
0 |
|
14 |
|
1 |
1. sketch not fully constrained |
Glendale , Arizona |
98 |
85 |
0 |
-2 |
15 |
|
1 |
Rest fillets' missing |
Omaha , Nebraska |
97 |
85 |
0 |
-2 |
14 |
|
1 |
1. Snapfit platform is not created properly 2.Rib sketch not fully
constrained |
Santa Ana , California |
97 |
85 |
0 |
-2 |
14 |
|
1 |
1.Snapfit platform goes through side cover 2.not rename features in
the browser |
Las Vegas , Nevada |
96 |
85 |
10 |
-8 |
9 |
|
1 |
1. Number of ribs is not correct(should be 10) 2.Both snapfits are
not closely fit into orange part 3.Switch control mounting base
lacks ribs 4. iproperty not fully populated 5.Projected geometry
not hide |
Columbus , Ohio |
96 |
85 |
0 |
-2 |
13 |
|
1 |
1.rib sketch not fully constrained 2.snapfit not fit closely with
orange side 3. Projected sketch component not hide |
Toledo , Ohio |
96 |
85 |
10 |
-6 |
7 |
|
1 |
# of ribs is wrong, base of snap need to be drafted, snap closeness,
iproperty missing, name features, name your file properly |
Laredo , Texas |
96 |
85 |
10 |
-8 |
9 |
|
1 |
fillet rest feature, # of ribs are wrong, press mount for green part
is wrong, hole for blue part is wrong, iproperty information
missing, close visibility of work planes and reference lines. |
Virginia Beach , Virginia |
95 |
85 |
0 |
-4 |
14 |
|
1 |
1. Feature requirement 4 is not correct. 2. Snapfit not closely fit
with side wire 3. File name was not revised, should contain your id |
Plano , Texas |
94 |
85 |
0 |
-6 |
15 |
|
1 |
1. No fillets on the backside of rest 2.Snapfit is too weak and not
fit closely with orange part 3. Snapfit platform is not correct |
Indianapolis, Indiana |
94 |
85 |
0 |
-6 |
15 |
|
1 |
1. No fillets on the backside of rest. 2.feature requirement 4 is
not fitting closely ot side wire 3. Snapfit does not fit in
closely |
Oakland , California |
94 |
85 |
0 |
-4 |
13 |
|
1 |
Snap fit closeness, sketches not fully constrained, turn off
visibility of planes and constraint |
El Paso , Texas |
94 |
85 |
0 |
-4 |
13 |
|
1 |
Rest features need to be filleted at back, snap fit closeness, name
your file properly |
Riverside , California |
93 |
85 |
0 |
-4 |
12 |
|
1 |
1. Rest base fillet is not correct 2. Snapfit is not fit closely
3. Snapfit goes through the frame case 4.iProperty not fully
populated(Author) 5.Sketch not fully constrained |
Los Angeles , California |
93 |
85 |
0 |
-2 |
10 |
|
1 |
1.Ribs number is not 10 2.iproperty was not fully populated(Your
name or id) 3.Rib sketch is not fully constrained |
Corpus Christi , Texas |
93 |
85 |
0 |
-4 |
12 |
|
1 |
1. Should Turn off visibility of local coordinate system 2. Should
Turn off visibility of workplane and projected geometry 3. Sketch
not fully constrained 4. Snapfit platform is not correct 4. No
fillets on the backside of rest |
Mesa , Arizona |
92 |
85 |
0 |
-2 |
9 |
|
1 |
1.File name not following naming rule. 2. iproperty not fully
populated(desiner/author) 3.Should Turn off visibility of all
sketches 4.Ribs sketch not fully constrained 5.Not using a rest
feature |
Buffalo , New York |
91 |
85 |
0 |
-2 |
8 |
|
1 |
wrong shape of feature 4, iproperty info is missing, sketches not
fully constrained, name your features |
Charlotte , North Carolina |
90 |
85 |
0 |
-8 |
13 |
|
1 |
# of ribs is wrong, switch mouting feature not completed, base for
snap fit not completed, snap fit closeness, sketches not fully
variable, name the features in the model |
St. Louis , Missouri |
90 |
85 |
0 |
-2 |
7 |
|
1 |
Snap fit closeness, iproperty information missing, fully constrain
your sketches, name your file properly |
Boston , Massachusetts |
88 |
85 |
0 |
-8 |
11 |
|
1 |
1.iproperty not fully populated(author/designer) 2.Should turn off
visibility of workplane/sketch 3.Ribs number is not correct(10),
rib distribution is not reasonable 4.No fillets on the backside of
rest 5. Feature requirement 4 is not fitting closely with side
wire, the dimension distance is not correct. 6. Snapfit does not fit
closely with orange side mount |
Raleigh , North Carolina |
88 |
85 |
0 |
-4 |
7 |
|
1 |
no draft angle of ribs, snap fit closeness, iproperty info is
missing, name your features, name your file properly |
Long Beach , California |
81 |
85 |
0 |
-12 |
8 |
|
1 |
1. Turn off visibility of all your sketch and workplane! 2.Adjust
the view position and angle before submit your homework 3.Rib
number is not correct, rib height is too low 4.Feature requirement
4 is not correct, dimension is not correct. 5.Snapfit platform is
not correct, not fit for molding 6. Rest is not correct, not
fillets on backside 7. Snapfit is too thick, not fit closely with
side mount 8. No rename of the features in browser 9. File name
is not following naming rule. 10.Boss on the rest is not correct.Too
big for assembling |
Washington , DC |
78 |
68 |
0 |
-4 |
14 |
|
1 |
Name features |
Baton Rouge , Louisiana |
0 |
|
|
|
|
|
1 |
No submission file/Quiz 1 attended |
Memphis , Tennessee |
0 |
|
|
|
|
|
1 |
No submission file/Quiz 1 attended |
Memphis , Tennessee |
0 |
|
|
|
|
|
1 |
No submission file/Quiz 1 attended |
|
|
|